Users Manual

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
75
WiBAS-Connect TS (Auto-Polarization Edition), Continued
Procedure for WiBAS-Connect Auto-Polarization TS with Parabolic Low Profile Antenna,
continued
Step
Action
3
Perform the following actions:
Connect the RSSI cable to TS (as described to RSSI cable connection procedure on
page 42).
If the commissioner power-on the unit and afterwards inserts the RSSI cable to
TS receptacle then the S/W will go to step 5.
Power on the terminal station and wait 3 minutes till the boot process is completed
- the led status of the terminal should be red.
Please do not perform any action till the boot process of the TS is completed.
After boot process the TS starts automatic process scan (vertical), and:
S/W selects F1 frequency (in vertical polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
S/W selects F2 frequency (in vertical polarization) and requires 10 seconds to
provide the QI value on the voltmeter.
For QI values please refer to QI table on page 93.
Continued on next page