Users Manual
WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
65
WiBAS-Connect TS, Continued
Procedure for WiBAS-Connect TS with Parabolic Low Profile Antenna,
continued
Step
Action
5a
Perform fine alignment, as follows:
• Use the spanner key to loosen the azimuth adjustment bolts (A). Perform azimuth
adjustment by holding tool’s handles firmly and slightly move the antenna/radio
combo (within the ±10
o
range around the azimuth axis) until the voltage readout
reaches a desired level.
(A) = Azimuth bolts x 2 (up and down)
The RSSI voltage (actually the voltmeter value) provides a direct
relationship with RSL.
For WiBAS-OSDR see
WiBAS-OSDR terminal station RSSI measurement
calculation formula on page 41,
For WiBAS-Connect see
WiBAS-Connect terminal station RSSI
measurement calculation formula on page 41).
6a Use the adjustable torque wrench for pre-tightening. The final tightening torque
will be applied after alignment process completion.
Continued on next page