Users Manual

WiBAS OSDR-Hub & Terminal Station / WiBAS-Connect Terminal Station
Start Up & Commissioning Manual - Edition 5.1
51
WiBAS-OSDR TS, Continued
Procedure for WiBAS-OSDR TS with Panel Antenna, continued
Step Action
3 Perform fine alignment, as follows:
Use the allen key to loosen the azimuth adjustment bolt (A). Perform azimuth
adjustment by moving very slowly the whole system (within the ±10
o
range around
the azimuth axis)
until the voltage readout reaches a desired level.
Use the allenr key to loosen the elevation adjustment bolt (E). Perform elevation
adjustment by moving very slowly the whole system (within the ±10
o
range around
the elevation axis) until the voltage readout reaches a desired value.
The RSSI voltage (actually the voltmeter value) provides a direct
relationship with RSL.
For WiBAS-OSDR see
WiBAS-OSDR terminal station RSSI measurement
calculation formula on page 41,
For WiBAS-Connect see
WiBAS-Connect terminal station RSSI
measurement calculation formula on page 41).
4 Use the adjustable torque wrench for pre-tightening. The final tightening torque
will be applied after alignment process completion.
Continued on next page