5
Safety Precautions
RF EXPOSURE
Locally applicable national and international RF safety requirements must be
adhered to when installing the OSDR / antenna system.
Please refer to local regulatory authorities for advice on compliance.
As guidance, for an OSDR 10.5 / 26 / 28 / 32 GHz:
According to EN 50385 and the relative EU Directives (1999/519/EC -
general public environment & 2004/40/EC occupational environment) the
OSDR / antenna, should be installed in a location such that it is not possible
for workers or members of the public, in the normal course of their work or
everyday activities, to gain access closer in front of the antenna than the
specified distances in the table below.
The values of the table are given for OSDR at max power and max gain 60
cm terminal antenna.
BAND (GHz) DISTANCE (meters)
WORKER PUBLIC
PtMP
Hub
PtMP TS or
PtP Node
PtMP
Hub
PtMP TS or
PtP Node
26 / 28 / 32 0.5 2.55 1 5.1
10.5 1.25 2.5