User Manual

StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual Edition 1.1
7
Assumptions
For reader’s convenience, we make the following assumptions
regarding the startup and commissioning procedure:
Site A
the location of the StreetNode
TM
6250 PTP node
that is closest to customer’s PoP (Point of Presence) and
is the node that will be installed first.
Site B
the location of the StreetNode
TM
6250 PTP node
that is farther away from customer’s PoP (with respect to
Site A
) and is the node that will be installed second.
“Local”
is meant the StreetNode
TM
6250 PTP unit that the
commissioner is directly connected to (using a laptop).
“Remote”
is meant the StreetNode
TM
6250 unit that the
commissioner is connected to remotely and by using a
laptop connected to
“local”
unit.
The StreetNode
TM
6250 PTP “Local” node, located closest to
network synchronization source, will retrieve synchronization
from its Gigabit Ethernet ports and will transport it to the next
terminating StreetNode
TM
6250 PTP node over the air
medium.
The StreetNode
TM
6250 PTP “Remote” node will retrieve
network synchronization from its modem port and will
transport it (to the next terminating StreetNode
TM
6250 PTP
node) through its Gigabit Ethernet ports.