Installation Manual

Table Of Contents
StreetNode™ 6250 PTP
Installation & Cabling Manual - Edition 2.1
27
Site Prerequisites, Continued
Grounding
Ensure the following:
To make a protective earth connection, use the grounding point located on
the radio unit using an, as short as possible, length of grounding cable of at
least 6mm
2
diameter (recommended 16mm
2
) or according to local electrical
code.
A grounding bar is required close to each equipment installation position.
Outdoor
grounding
system
An appropriate, low-resistance grounding system as specified by the local
regulations is required.
A grounding point (designated GND) should be located close to the
mounting position of the equipment.
The equipment will be connected to this grounding point, via the supplied
grounding cable.
This can also provide partial protection against Lightning-induced current.
For additional protection against lightning LSPs need to be used.
For more information regarding the installation of LSP/PSP please refer to
the following manual:
Lightning & Surge Protection for Intracom Telecom Radios Installation
Practices
Continued on next page