User's Manual
Table Of Contents
StreetNode 6250 PTP with Embedded Node Manager
WebGUI Commissioning Manual - Ed1.1
-VII-
Radiation Safety, Continued
Compliance
boundary
definition
The Compliance Boundary Definition for StreetNode
ΤΜ
6250 PTP is shown to
the following table below:
Parameter
Value
Max EIRP 40,0
dBm
10,0
W
Max EIRP (worst case conditions) ~47,0
dBm
~50,00
W
Power Flux Density Limit (General Public) 10,0
W/m
2
Compliance Boundary (General Public)
0,64
m
Power Flux Density Limit (Occupational) 50,0
W/m
2
Compliance Boundary (Occupational) 0,29
m
The above calculations are based on information available at the
time of issue of the current document.
RF exposure compliance boundary studies / reports are available
upon request.
References
-
1999/519/EC, COUNCIL RECOMMENDATION of 12 July 1999
on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz).
- OET Bulletin 65, Evaluating Compliance with FCC Guidelines for
Human Exposure to Radiofrequency Electromagnetic Fields,
Edition 97-01, August 1997.
- GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING
ELECTRIC, MAGNETIC, AND ELECTROMAGNETIC FIELDS
(UP TO 300 GHz), International Commission on Non-Ionizing
Radiation Protection (ICNIRP), 1998