LED CODE CHART
E90
No water fl ow
•
Turn off and unplug the control unit.
•
Ensure the outlet cover grid is clean and free
from obstructions.
•
Clean or replace the cartridge, see
Maintenance and Storage section.
•
Ensure the in/outlet connections on the spa tub
and fi lter pump are not blocked.
•
Keep the spa water properly sanitized to
ensure a clean and unclogged fi lter cartridge.
•
If problem persists, contact Intex Service
Center.
E94
Water temperature too low
•
If the ambient temperature is below 39°F (4°C),
we recommend not to use the spa.
•
Turn off and unplug the control unit, add some
warm water to raise the spa water temperature
above 5°C (41°F), then press the button to
heat up the water to the desired temperature.
•
Press the temperature increase button to set
the desired water temperature.
•
If problem persists, contact Intex Service
center.
E95
Water temperature too high
•
Turn off and unplug the control unit. When the
water has cooled down, plug the GFCI/RCD
and restart all over again.
•
Turn the heater off, then press the fi lter and
bubble buttons to lower the water temperature.
•
If problem persists, contact Intex Service
Center.
E96
System Error
•
Turn off and unplug the control unit. Plug the
GFCI/RCD and restart all over again.
•
If problem persists, contact Intex Service
Center.
E99
Water temperature sensor broken
•
Contact Intex Service Center.
END
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The rapid
heating and water fi ltration
functions are disabled.
•
Press the button to re-active the fi lter
pump.