Operation Manual
(110GS) MODEL 634RC FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/15/2016
110
GS
SAVE THESE INSTRUCTIONS
English
Page 10
1.
Make sure the filter pump is switched off. The switch is located on the motor housing.
2.
Connect the power cord to a GFCI protected electrical outlet.
3.
Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve,
allowing water to flow into the filter pump.
4.
With water flowing into filter pump, the water pressure will allow the air trapped inside to
escape from the air release valves
(2 & 7)
. When all the air has escaped water will flow out of
the valves
(2 & 7)
. When this occurs gently finger tighten the valves
(2 & 7)
in a clockwise
direction.
5. To operate the filter pump on “TIMER” mode:
A. Set the timer dial to the desired operating hours. See operation time table. See Fig. 12.
B. Turn on the pump by pressing the switch to “ ” position, the filter pump is now filtering
the water and will stop after the operating hours are completed. The built-in timer will now
operate for the number of hours selected at the same time each day.
C. Operating hours can be re-adjusted if necessary. Follow step A – B.
To operate the filter pump manually (without the “TIMER” mode):
A. Turn on the pump by pressing the switch to “I” position, the filter pump is now filtering the
water.
B. To turn off the pump, press the switch to “O” position.
6.
Never put pool chemicals directly into the filter pump. This may damage the pump and void
the warranty.
IMPORTANT
To prevent air lock, open the lower plunger valve (connected inlet hose) first and then
the upper plunger valve (connected outlet hose). Open the air release valves, wait until
water starts to flow out of the air release valves, close air release valves.
OPERATING INSTRUCTIONS
WARNING
Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD).
Contact a qualified electrician if you cannot verify that the receptacle is protected by
a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum
rate of 30 mA. Do not use a portable residual current device (PRCD).
ON
OFF
TIMER
TIMER DIAL (HOURS)
RCD OPERATING INSTRUCTIONS
• Plug RCD into power outlet. Press RESET button on the RCD plug. Indicator should be "ON".
See FIG. 10.
• Press TEST button on the RCD plug. Indicator should be "OFF". See FIG. 11.
• Press RESET button for use. Do not use if test fails. Contact a qualified electrician to
determine cause of failure.
RESET
RESET
TEST
TEST
10
RESET
RESET
RESET
TEST
TEST
11
TEST
FIG 12