LED CODE CHART
IMPORTANT
When Code “90” alarm is shown, ensure the timer of the filter pump is set
one (1) hour longer than the Saltwater System.
If the filter pump does not have a built-in timer, the filter pump needs to
be turned on/off manually every day.
LED Reading Definitions
80 BoostMode
00 Stand-ByMode(Start-up)
01 MinimumOperatingHour(1hourremaining)
02 OperatingHours(2hoursremaining)
03 OperatingHours(3hoursremaining)
04 OperatingHours(4hoursremaining)
05 OperatingHours(5hoursremaining)
06 OperatingHours(6hoursremaining)
07 OperatingHours(7hoursremaining)
08 OperatingHours(8hoursremaining)
09 OperatingHours(9hoursremaining)
10 OperatingHours(10hoursremaining)
11 OperatingHours(11hoursremaining)
12 MaximumOperatingHours(12hoursremaining)
90 AlarmCode(LowPumpFlow/NoPumpFlow)
91 AlarmCode(LowSaltLevel)
92 AlarmCode(HighSaltLevel)
93 Stand-ByMode(OperatingProcessfinished)
“BLANK” NoPoweror“PowerSavingMode”waitingtostartnext
Saltwater System cycle.