(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 English 189 PO OWNER’S MANUAL IMPORTANT SAFETY RULES Read, understand, and follow all instructions carefully before installing and using this product. Krystal Clear Saltwater System® & Filter Pump Model CS7111 For illustrative purposes only.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish TABLE OF CONTENTS Warnings......................................................................... 3 Parts References............................................................ 4-5 Product Information & Specifications.......................... 6 Setup Instructions.......................................................... 7-10 Salt & Pool Water Volumes...........................................
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish IMPORTANT SAFETY RULES Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product. READ AND FOLLOW ALL INSTRUCTIONS WARNING • To reduce the risk of injury, do not permit children to use this product. Always supervise children and those with disabilities. • Children must stay away from this product and electrical cord(s).
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO PARTS REFERENCE Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. 1 2 3 8 4 5 7 6 2 1 9 31 10 14 37 38 32 39 18 11 40 12 15 17 16 13 30 8 * 35 21 22 23 24 25 * 35 19 19 20 20 * 19 20 35 21 26 27 28 21 * 35 22 23 21 26 24 27 29 19 20 " * ": Optional.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO PARTS REFERENCE (continued) Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts. REF. NO. SMALL AGP LARGE AGP COMMON PARTS DESCRIPTION QTY. SPARE PART NO.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish HOW SANITIZER IS GENERATED This product is specially designed for above ground pools. It will destroy the bacteria, oxidize bather organics and control algae, which provide a safe, clean and comfortable swimming pool. Common salt (sodium chloride) is made up of two elements, sodium and chlorine.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish STRAINER & PLUNGER VALVE SETUP IMPORTANT The Saltwater System/Filter Pump must be installed as the last piece of pool equipment in the water return line to the pool. This location extends the life of the titanium plates. Strainer & Plunger Valve Setup (small AGP) The strainer grid prevents large objects from jamming and/or damaging the filter pump.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 189 PO EnglishEnglish POOL OUTLET - STRAINER & PLUNGER VALVE SETUP (OPTIONAL) The strainer grid prevents large objects from jamming and/or damaging the filter pump. If your pool has an inflatable top ring, install the strainer, nozzle and plunger valve before inflating the pool liner top ring. The part numbers here onward refer to the parts depicted in the Parts List section of this manual.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish POOL INLET - NOZZLE & PLUNGER VALVE SETUP (OPTIONAL) 1. Grasp the nozzle and plunger valve mechanism. 2. In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (24) (see drawing 5). Be careful not to lose the step rubber washer (21). Place the plunger valve on the ground in a safe place. 3.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish SALTWATER SYSTEM/FILTER PUMP Saltwater System/Filter Pump 1. Remove the Saltwater System/Filter Pump and hoses from the packaging. 2. Place the Saltwater System/Filter Pump in a location for hose (8) connections to the plunger valve assemblies. NOTE: Some regional regulations may require the filter pump to be mounted on a stationary platform.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish SALT & POOL WATER VOLUMES • Which kind of salt to use: Use only Sodium Chloride Salts Use only sodium chloride (NaCl) salt that is at least 99.8% pure. It is also acceptable to use water conditioning salt pellets (the compressed forms of evaporated salt). However, it will take a longer time for them to dissolve. Do not use iodized or yellow (yellow prussiate of soda) colored salt.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish INTEX POOLS SALT TABLE This table shows the amount of salt needed to achieve and maintain the optimal 3000 ppm salt level. Pool Size Water Capacity (Calculated at 90% for Frame Pool and 80% for Easy Set & Oval Pool) Salt Needed for Startup 3.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO INTEX POOLS CYANURIC ACID TABLE Cyanuric acid is a chemical that reduces the loss of chlorine in water due to ultraviolet rays. To maintain the pool water clear and clean, and to maximize the performance of the device, add cyanuric acid to the pool. We recommend that the cyanuric acid level be maintained at approximately 1% of the salt, i.e. 100 Lbs (45 Kgs) salt x1% = 1 Lbs (0.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO SALT CALCULATION FORMULA FOR ALL POOLS Salt Needed for Startup (Lbs) Salt Needed for Startup (Kgs) Water Capacity (Gals) x 0.025 Water Capacity (Liters) x 0.003 Salt Needed when Salt Needed when Low Salt Detected (Lbs) Low Salt Detected (Kgs) Water Capacity (Gals) x 0.0067 Water Capacity (Liters) x 0.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish FILTER PUMP OPERATION 1. Make sure the unit is switched off. The switch is located on the control station. 2. Connect the power cord to a GFCI protected electrical outlet. WARNING Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI).
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish SALTWATER SYSTEM OPERATION 1. Start up the unit: Plug the power cord into the electrical outlet and test the GFCI/RCD (circuit breaker). Switch on the unit. With the Filter Pump turned “ON” and operating. The green "Pump" light on the control panel will be on and flashing code “00” appears on the electronic control station’s LED, indicating that the unit is ready to be programmed.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish SALTWATER SYSTEM OPERATION (continued) 6. Boost cycle • If the test result is below 0.1ppm, press and hold “BOOST” button for 5 seconds until the indicator lights up and the LED display display “80”. This indicates that the saltwater system has started copper ion and more chlorine sanitizer production.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish MAINTENANCE WARNING Always unplug this product from the electrical outlet before removing, cleaning, servicing or making any adjustment to the product. IMPORTANT Close plunger valves on your pool or insert black hat-like plugs in strainer opening to prevent water spillage. Open plunger valves or remove plugs when maintenance is completed. FLOW SENSOR CLEANING 1.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish MAINTENANCE (continued) 1. Switch off the unit, unplug the power cord from the electrical socket. 2. Turn both plunger valve handles fully clockwise until they stop. This closes the valve, prevents the water from flowing out of the pool. 3. Disconnect the hose with nut (8) from the Saltwater System, and assemble the cell cover (30) at the side of the cell. 8 30 4.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish CLEANING OR REPLACING FILTER CARTRIDGES It is recommended that the filter cartridge be replaced at least every 2 weeks. 1. Make sure the unit is turned off, and disconnect the power cord from the electrical outlet. 2. Turn both plunger valve handles fully clockwise until they stop. This closes the valve, prevents the water from flowing out of the pool. 3.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish MAINTENANCE (continued) INTEX COPPER ION TEST STRIPS (PACKED WITH THE PRODUCT) ® The Copper Ion Test Strips can be used to test the copper ion concentration in the water. Directions and Use 1. Dip the entire strip into the water for 3 seconds, then remove it 2. Hold the strip level for 15 seconds. Donot shake excess water from the strip. 3.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish POOL MAINTENANCE & CHEMICAL DEFINITIONS Preferred Water Chemistry Reading Minimum Ideal Maximum Copper Ions 0 0.1 - 0.2 ppm 0.2 ppm Free Chlorine 0 0.5 - 3.0 ppm 5.0 ppm Combined Chlorine 0 0 ppm 0.2 ppm pH 7.2 7.4 - 7.6 7.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION FILTER MOTOR FAILS • The motor is not plugged in. • Switch is not turn on. TO START • The GFCI circuit breaker is tripped. • Motor too hot and overload protection is shut off. • Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter, or RCD. • Reset circuit breaker.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO TROUBLESHOOTING GUIDE (continued) PROBLEM CAUSE SOLUTION INSUFFICIENT CHLORINE • Insufficient operating hours of the Saltwater System. • The salt level in the pool water is less than 2000ppm. This is insufficient. • Chlorine loss due to intense sunlight exposure. • The bather load has increased. • Clogged or dirty electrolytic cell. • High UV level exposure.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO TROUBLESHOOTING GUIDE (continued) LED PANEL CODE PROBLEM SOLUTION LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing). 1. Circulation line is blocked. 2. Incorrect inlet and outlet hose direction. • If your unit has plunger valves, ensure that they are open. • Clear your filter cartridge and cell from debris and dirt. See “Maintenance”.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish GENERAL AQUATIC SAFETY Water recreation is both fun and therapeutic. However, it involves inherent risks of injury and death. To reduce your risk of injury, read and follow all product, package and package insert warnings and instructions.
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013 EnglishEnglish 189 PO LIMITED WARRANTY ® Your Krystal Clear Saltwater System has been manufactured using the highest quality materials and workmanship. All Intex products have been inspected and found free of defects prior to leaving the factory. This Limited Warranty applies only to the Krystal Clear ® Saltwater System and accessories listed below.