TROUBLESHOOTING GUIDE
INSUFFICIENT
CHLORINE
INSUFFICIENT
COPPERION
LEVEL
POOLISSTAINED
WHITEFLAKESIN
THE WATER
NOLEDDISPLAY
GREENHAIR
• Insufficient operating hours of
the Saltwater System.
• The salt level in the pool water
is less than 2000ppm. This is
insufficient.
• Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
• Insufficient operating hours.
• The PH is too high.
• The bather load has increased.
• Clogged or dirty copper
electrode.
• Copper electrode defective.
• High copper ion concentration.
• Excessive calcium hardness is
present in pool water.
• Nopowersupply.
• RCD/GFCIhasnotreseted.
• A power fuse has blown.
• LED failure.
• Incorrectswitching,presstwo
buttons ( and ) together.
• High copper ion concentration.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Check the salt level with the Test Kit. Adjust
asneeded.See“Salt&PoolWaterVolumes”.
•
Use a pool cover when the pool is not in
use and/or when the unit is operating.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
• Cover the pool with a pool cover for 2
days with the device running and then
test the water using the test strips.
• If the pool is clean and clear, add stabilizer
to the water
and then test the water with the
device running.
• Increase operating time per day. See
“Operating Instructions”.
• Use PH decrease chemical to adjust,
contact your local pool chemical store.
• Increase the operating time per day.
See “Operating Instructions”.
• Remove the cell for inspection, clean it
if necessary. See “Maintenance”.
• Contact Intex Service Center.
• Drainabout20%ofthepoolwaterand
add fresh water to decrease the copper
ion concentration below 0.2ppm.
• Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Usealemonbasedcleaningproduct
(preferably containing citric acid). Don’t
scrub with aggressive cleaning
products because this might etch the
underlying surface.
• Drainabout20to25%ofthepool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
•
Plug the cell cord firmly into the cell housing
receptacle.
•
ResettheRCD/GFCI.
•
Contact Intex Service Center.
•
Contact Intex Service Center.
•
Shut down and turn on the power again,
re-set the time. See “Operating Instructions”.
• Drainabout20%ofthepoolwaterand
add fresh water to decrease the copper
ion concentration below 0.2ppm.
• Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Use‘Ultra-Swim’shampoo,orshampoo
containing chelating agents.