TROUBLESHOOTING GUIDE
• Themotorisnotpluggedin.
• Switchisnotturnon.
• TheGFCIcircuitbreakeris
tripped.
• Motortoohotandoverload
protection is shut off.
• ImpropersanitizerorpHlevels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenis
restricting the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Thevacuumreleasevalve
on the plunger valve is
activated.
• Thevacuumreleasevalve
on the plunger valve is
leaking.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Anairlockinsidethecartridge
chamber and motor chamber.
• Servicelighton.
• O-ringmissing.
• Coverisnottight.
• Filtercartridgeisdirty.
•Hosenutsarenotwell-fitted.
• There’sairtrappedinthepump
housing and inlet hose.
• Theinletandoutlethoses
connection are reversed.
PROBLEM
CAUSE SOLUTION
FILTER MOTOR
FAILS TO START
FILTERDOESN’T
CLEANPOOL
FILTERDOESN'T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMPDOESN'T
WORK
TOP COVER
LEAKING
HOSELEAKING
AIR LOCK
• Filtercordmustbepluggedintoa3wire
outlet that is protected by a Class A
GroundFaultCircuitInterrupter,orRCD.
• Resetcircuitbreaker.Ifcircuitbreaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Letmotorcooldown.
•
Adjust the sanitizer and pH level. Consult
your local swimming pool supply stores.
• Cleanorreplacecartridge.
• Checkthecartridgeforholes.Replace
if damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintake
hose by discharging it inside pool wall.
• Tightenhosenuts,checkhosesfor
damage, check pool water level.
• Replacecartridge.
• Cleancartridgemoreoften.
• Cleaninsidetheplungervalve.
• Pullvalvehandletofulluprightposition.
• Turnoffpump,clearanydebrisorobstructionin
the outlet, remove all air from the filter pump and
turn pump on again.
• Turnoffpump,ifwaterleakingfromthevacuum
release valve, then release valve needs to be
replaced. Contact Intex Service Center
immediately to order replacement. You may cover
release valve with the cap temporarily if you
ensure that the strainer cover / strainer grid is
installed and you Do Not run the pump while
pool is occupied.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhosenuts,checkhosefor
damage.
• Clearanysticksorleavesintheintake
hose.
• Turnandpullvalvehandletofullupright
position.
• Unscrewtwoairreleasevalveonthe
chamber to fullfill water.
• ContactIntexServiceCenter.
• Removecover&checkforO-ring.
• Tightencover(Manually).
• Replaceorcleancartridge.
•Tightenorreinstallhosenut.
• Openairreleasevalves,liftandlower
the inlet hose until water starts to flow
out of the valve, then close it.
• Thelowerpositionofpooloutlet
connects to filter pump water inlet. The
upper position of pool inlet connects to
filter pump water outlet.