CS7111 Krystal Clear Saltwater System 2013 User Manual
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 07/31/2012
189
PO
SAVE THESE INSTRUCTIONS
Page 28
English
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE
• Themotorisnotpluggedin.
• Switchisnotturnon.
• TheGFCIcircuitbreakeris
tripped.
• Motortoohotandoverload
protection is shut off.
• ImpropersanitizerorpHlevels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenis
restricting the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Thevacuumreleasevalve
on the plunger valve is
activated.
• Thevacuumreleasevalve
on the plunger valve is
leaking.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Anairlockinsidethecartridge
chamber and motor chamber.
• Servicelighton.
• O-ringmissing.
• Coverisnottight.
• Filtercartridgeisdirty.
•Hosenutsarenotwell-fitted.
• There’sairtrappedinthepump
housing and inlet hose.
• Theinletandoutlethoses
connection are reversed.
PROBLEM
CAUSE SOLUTION
FILTER MOTOR
FAILS TO START
FILTERDOESN’T
CLEANPOOL
FILTERDOESN'T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMPDOESN'T
WORK
TOP COVER
LEAKING
HOSELEAKING
AIR LOCK
• Filtercordmustbepluggedintoa3wire
outlet that is protected by a Class A
GroundFaultCircuitInterrupter,orRCD.
• Resetcircuitbreaker.Ifcircuitbreaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Letmotorcooldown.
•
Adjust the sanitizer and pH level. Consult
your local swimming pool supply stores.
• Cleanorreplacecartridge.
• Checkthecartridgeforholes.Replace
if damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintake
hose by discharging it inside pool wall.
• Tightenhosenuts,checkhosesfor
damage, check pool water level.
• Replacecartridge.
• Cleancartridgemoreoften.
• Cleaninsidetheplungervalve.
• Pullvalvehandletofulluprightposition.
• Turnoffpump,clearanydebrisorobstructionin
the outlet, remove all air from the filter pump and
turn pump on again.
• Turnoffpump,ifwaterleakingfromthevacuum
release valve, then release valve needs to be
replaced. Contact Intex Service Center
immediately to order replacement. You may cover
release valve with the cap temporarily if you
ensure that the strainer cover / strainer grid is
installed and you Do Not run the pump while
pool is occupied.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhosenuts,checkhosefor
damage.
• Clearanysticksorleavesintheintake
hose.
• Turnandpullvalvehandletofullupright
position.
• Unscrewtwoairreleasevalveonthe
chamber to fullfill water.
• ContactIntexServiceCenter.
• Removecover&checkforO-ring.
• Tightencover(Manually).
• Replaceorcleancartridge.
•Tightenorreinstallhosenut.
• Openairreleasevalves,liftandlower
the inlet hose until water starts to flow
out of the valve, then close it.
• Thelowerpositionofpooloutlet
connects to filter pump water inlet. The
upper position of pool inlet connects to
filter pump water outlet.