MAINTENANCE (continued)
MMAAIINNTTEENNAANNCCEE
1. Disconnect power cord from electrical outlet.
2. After pool is emptied of all water, disconnect the Saltwater System from the
hoses reversing the installation instructions.
3. Air-dry the unit before storage (It may be prudent to visually inspect and clean
the electrolytic cell at this time).
4. Store the unit and accessories in a dry, temperature controlled, between 32
degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit (40
degrees Celsius) storage location.
5. The original packing carton can be used for storage.
3-Way Test Strips can test the “Free Chlorine”, “pH”, and “Total Alkalinity” levels at
the same time. Directions and Use:
1. Dip entire strip into water and remove immediately.
2. Hold strip level for 15 seconds (do not shake excess water from strip).
3. Compare free chlorine, pH and total alkalinity strip pad to the color chart on
packaging label. Adjust pool water as necessary. Proper technique is important
for water testing. Be sure to read and follow the written strip instructions.
INTEX
®
3-WAY TEST STRIPS (PACKED WITH THE PRODUCT)
LONG TERM STORAGE
English
6. If flushing does not remove the deposits on the plate then disconnect the cell
from the base by removing the 4 mounting screws (3). Disconnect the flow
sensor from the top of the cell and unplug the electrolytic cell cord. Assemble
the cell cover (11) onto the bottom of cell and pour the kitchen grade vinegar
into to cell until all titanium plates are immersed, soak for 2-3 hours and then
flush with high pressure water from the garden hose.
7. Reconnect electrolytic cell reversing steps 3, 4, 5 and 7. (Reset the Saltwater
System’s operating hours)
NOTE: After cleaning the operating hours have to be reset.