ALARM CODES
No chlorine production will occur if “Low Water Flow”, “Low Salt Level” or “High Salt
Level” are detected. If any of these conditions occur then the Saltwater System will
sound an alarm that indicates chlorine production has stopped. A buzzer will sound
and a Code (see below) will keep flashing on the LED for 1 hour. The buzzer and
flashing light will end after one hour and the Saltwater System will go to Power
Saving Mode. If this occurs then press any button ( or ) to view the code of
the original problem so that it can be corrected.
Turn off the power of the unit and follow the solutions below to solve the problem.
Turn on the unit again by following the “Operating Instructions”.
AALLAARRMMSS
English
Code Cause Remedy Flashing Buzzer
1. Circulation line
blocked.
2. Incorrect inlet and
outlet hose
direction.
3. Flow sensor
conduit incorrectly
installed.
4. Scale on the flow
sensor.
5. Flow sensor cord
is loose.
6. Flow sensor failure.
1. Dirt or scale on
titanium plates.
2. Low salt level / No
salt.
3. Electrolytic cell
cord is loose.
4. Possible electrolytic
cell failure.
1. High salt level.
Ensure the plunger valves are
opened (if any).
Ensure your filter cartridge, cell are
clear from debris and dirt. See
“Maintenance”.
Release all trapped air in the
circulation line. See Filter Pump
Manual.
Check for the direction of water
inlet and water outlet hose. Reverse
the hoses if necessary. See “Set
Up Instructions”.
Check for the arrow on the follow
sensor conduit toward the same
direction with the one on the cell.
Reverse the follow sensor conduit if
necessary.
Ensure the flow sensor (especially
the hinge) is clean. See “Maintenance”.
Check for flow sensor loose or not
connected properly. Plug the flow
sensor firmly into the flow sensor
receptacle.
Contact Intex Service Center for
replacement.
Remove the electrolytic cell for
inspection and clean it if necessary.
See “Maintenance”.
Add salt. See “Salt & Pool Water
Volumes”.
Check to see if cell cord is loose or
not connected properly. Ensure the
cell cord is plugged firmly into the
cell housing receptacle.
Contact Intex Service Center.
Replace the cell if needed.
Partially drain the pool and refill
with fresh water. See “Salt & Pool
Water Volumes”.
Low
Water
Flow or
No Flow
Low Salt
Level
High Salt
Level
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s