After the salt is dissolved, but before starting the Saltwater System be sure
that:
The entire filtering and chlorinating system is connected to a grounding type
receptacle protected by a ground-fault circuit interrupter (GFCI).
The filter pump operates several minutes before starting the Saltwater System
(This removes air pockets and debris in the water hoses).
No air is trapped in any of the hoses (Follow the Filter Pump Owner’s manual
to release any trapped air).
1. Plug the power cord into the electrical outlet. Switch on the
unit. Code “88” appears on the electronic control station’s
LED indicating the unit is in a Stand-By Mode, this is normal.
2. Unlock keypad controls:
Press and hold button for 2 seconds until you hear a
short “beep”, then press and hold button for another 2
seconds until you hear the second short “beep”, LED flashes
“00”. This procedure unlocks the keypad control buttons.
3. Set Saltwater System operating hours:
Increase the scheduled number of hours of
operation by pressing button, or reduce
by pressing button. See “Operating Time
Table” for pool size and required operating
hours. Press button to select hours
required, press if too many hours were
selected. The built-in timer will now operate
for the number of hours selected at the
same time each day.
NOTE: The Saltwater System will not operate if the filter pump is not operating.
4. Re-lock keypad controls:
With the proper hour value showing, press and hold button
for 2 seconds until you hear a long “beep”, then press
and hold button for another 2 seconds until you hear the
second long “beep”. A green “CHLORINE” light on the control
panel will light up within a few minutes, which indicates the
saltwater system starting chlorine production. With locking the
control buttons into this setting you will have prevented
unauthorized changing of the operating cycle.
NOTE: If you forget to Re-lock the keypad controls, the salt system will
automatically lock the keypad controls and start working 1 minute later.