Operation Manual
(57) MODEL 603 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 08/06/2012
57
SAVE THESE INSTRUCTIONS
Page 9
English
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE
• Filtercordmustbepluggedintoa3
wire outlet that is protected by a Class
AGroundFaultCircuitInterrupter.
• Resetcircuitbreaker.Ifcircuitbreaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Letmotorcooldown.
• AdjustthechlorineandpHlevel.Consult
your local swimming pool supply stores.
• Cleanorreplacecartridge.
•
Check the cartridge for holes.
Replace if
damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintake
hose by discharging it inside pool wall.
• Tightenhoseclamps,checkhosesfor
damage, check pool water level.
• Replacecartridge.
• Cleancartridgemoreoften.
• Installthenozzleattheupperposition
of the pool inlet, and the strainer at the
lower position of the pool outlet.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhoseclamps,checkhosefor
damage.
• Clearanysticksorleavesinthe
intake hose.
• Openthereleasevalveattopofpump.
• Removecover&checkforO-ring.
• Tightencover(Manually).
• Replaceorcleancartridge.
• Tightenorreinstallhoseclamps.
• Openairreleasevalve,liftandlower
the inlet hose until water starts to flow
out of air release valve, close air
release valve.
FILTER MOTOR
FAILS TO START
FILTER DOESN’T
CLEAN POOL
FILTER DOESN’T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMP DOESN’T
WORK
TOP COVER
LEAKING
HOSELEAKING
AIRLOCK
• Themotorisnotpluggedin.
• Thefuseboxneedschecking.
• TheGFCIcircuitbreakeris
tripped.
• Motortoohotandoverload
protection is shut off.
• ImproperchlorineorpH
levels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenis
restricting the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Nozzleandstrainer
connection are reversed.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Faultymotorortheimpeller
is jammed.
• Anairlockinsidethecartridge
chamber.
• O-ringmissing.
• Coverisnottight.
• Filtercartridgeisdirty.
• Hoseclampsarenot
well-fitted.
• There’sairtrappedinthe
pump housing and inlet hose.
TROUBLE
CAUSE
SOLUTION