GPS Connection FOR CM 169CS
QUICK DISCONNECT BRACKET CABLE
DESCRIPTION
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
BROWN
GRAY
ORANGE
PINK
BLUE
PWR-/GND/COMMON
POWER +10-35Vdc
INPUT 1+
COMMON
OUTPUT 1+
INPUT 2+
OUTPUT 2+
INPUT 3+
OUTPUT 3+
COMMON
POWER
SUPPLY
+
SMART GPS
SENSOR
GPS POWER
SWITCH
DIFFERENTIAL
BEACON
RECEIVER
RTCM 104 OUTPUT+
SIGNAL RETURN
FUNCTION
SMART GPS SENSOR CABLE
RED
BROWN
GREEN
WHITE
BLACK/YELLOW/SHIELD
POWER +10-35 Vdc
GPS NMEA0183 OUTPUT+
GPS NMEA0183 INPUT+
RTCM 104 INPUT+
GND/SIGNAL RETURN
WIRE COLOR
FUNCTION
GPS Connections on Port 3
C-COM GSM Plus Connection
To connect the modem C-COM to the chart plotter with quick disconnect bracket
follow the procedure:
1. Cut the C-COM cable about 5 cm from the "T" connector:
2. Connect the wires to the quick disconnect bracket cable as follows:
QUICK DISCONNECT BRACKET CABLE
DESCRIPTIONWIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
POWER SUPPLY GND
POWER SUPPLY+
C-COM
C-COM
C-COM
POWER GND
POWER +10-35Vdc
INPUT 1+
COMMON
OUTPUT 1+
FUNCTION
C-COM GSM Plus CABLE
WIRE COLOR
BLACK
RED
WHITE
GREEN
YELLOW
GND
POWER SUPPLY+
C-COM TX+
C-COM TX-
C-COM RX+
FUNCTION
Connection for the port 1
www.busse-yachtshop.de | info@busse-yachtshop.de