User's Manual
Action Press Details
24. Set/clear event
log mask
73 # event # set/clear # **
See options below;
all events are
logged by default
unless stated
otherwise below
Event
1 access denied - invalid PIN
2 program denied
4REX
5 Propped Door
6DoorClosed
7 Forced Door
16 log dumped by user #N
17 access granted to user #N
19 access denied to user #N, bad
timezone
20 toggle mode activated by user #N
(latch set)
21 toggle mode de-activated by user
#N (latch clear)
22 1st in auto-unlock triggered by
user #N
23 door relocked by user #N
24 user lockout enabled by user #N
25 user lockout disabled by user #N
26 access denied to user #N - user is
disabled
27 card/code mismatch
29 program mode started by user #N
30 log erased by user #N
32 unprogrammed card data
33 unprogrammed code data
50 log retrieved
51 access denied to user #N, user
group lockout
Events 30 and 50
cannot be disabled
Events 32 and 33
are disabled by
default
25. Reset (erase)
transaction log
76 # 00000 # 00000 # **
26. To exit Program
mode
* (after final command) Yellow stops flashing
Chapter 4: Programming 4.6 Programming Commands
4-40 prox.pad plus Install/Program. Manual, PPP, D2