User's Manual
Action Press Details
7. Change keypad
parameters
32 # parameter # value # **
See options below
Parameter Value
0-error lockout threshold 1-50 (def=3)
1-error lockout duration 1-255 (def=10
sec)
3-extended unlock time 1-255 (def=10
sec)
4-site ID (for cmds 51, 57) 0-255 (def=11)
5-user timezone mask 0-255 (def=255)
(for programming users
through the faceplate)
6-user lockout group 0-15 (def=4)
7-lockout by group 0-3 (def=0)
operand (see below)
0=lockout users in all other
groups
1=lockout users in this
group (except lockout users)
2=lockout users in higher
numbered groups
3=lockout users in lower
numbered groups
8-Anti-Passbackdelay 2-240(1/4sec
increments, def=
4or1sec)
8. Set/clear
auto-unlock mask
38 # autz # set/clear # * *
autz - auto-unlock
timezone (1-8)
Entering a 1 sets
the timezone as
auto-unlock and a 0
clears it
9. Restore system
defaults (master
user and system
options/parameters
only)
40 # 00000 # 00000 # * *
Chapter 4: Programming 4.6 Programming Commands
4-36 prox.pad plus Install/Program. Manual, PPP, D2