When either the Master or Supervisor is pro-
grammed as “card AND c ode,” both are required
to enter Program mode.
When they are programmed fo r “card OR code,”
only the card is required to enter Program mode.
IftheMasterorSupervisorisprogrammedfor
“card OR cod e” and you want them to require
both to enter Program mode, enable option 3 using
command30(30#3#1#**).
4.1.1.D prox.pad plus Default Settings
Table 4-1 lists the default settings for the prox.pad plus
unit as shipped from the factory. Subsequent sections
in this chapter explain how to change these default
settings or program additional functions.
Table 4-1. prox.pad plus Default Settings
Parameter Default S etting
Main Relay Lock Output
Auxiliary Relay Alarm shunt function
Audio Alert #1 Forced Door
Audio Alert #2 Propped Door
Master Code (user one) 1234*
Main Relay energizes for Five (5) seconds
Audible Keypress Feedback ON
Propped Door Output activates after Thirty (30) seconds
Forced Door Output activates for Ten (10) seconds
4.1 Programming Overview Chapter 4: P rogramming
prox.pad plus Install/Program. Manual, PPP, D2 4-3