User's Manual
Document # 6045000 Rev 1.0 PRELIMINARY
1
RS-232 to RS-485 Converter Installation Instructions
Specifications:
Mechanical Electrical:
2.74” W x 4.6” L x 1.4” H Operating Voltage: 12-24 VAC/DC
Current Draw: XXmA (typical)
Environmental:
Environment: For indoor use only.
Temperature Tolerance: -20º to 130º F
Description:
The IEI RS-232 to RS-485 Converter is used to communicate with an RS-485 device using a PC. A computer
COM port communicates using RS-232 protocol and the converter is required to convert the data to RS-485.
Packing List:
1 RS-232 to RS-485 Converter
1 Installation Instructions
1 6-foot straight cord
1 DB-9 Serial Connector
1 DB-25 Serial Connector
Connecting power to the converter
The converter can be powered with 12 to 24 Volts AC or DC. The power supply is connected to the V+ (pin 1),
V- (pin 2) and EGND (pin 3) terminals on TS1. The diagram on the next page shows the terminal strip
location. To access the terminal strip you must remove the cover. The cover is secured with 4 screws on the
bottom side.
Connecting the RS-485 device
The RS-485 device is connected to the Data A (pin 4), Data B (pin 5) and Data GND (pin 6) terminals on TS1.
The diagram on the next page shows the terminal strip location. To access the terminal strip you must remove
the cover. The cover is secured with 4 screws on the bottom side.
The recommend cable for RS-485 networks is 24 AWG, shielded two twisted-pair telephone cable with a shunt
capacitance of 16pF/Ft. Devices can be wired up to 4000 feet from the converter. When connecting multiple
devices to the converter wire them in parallel.