User's Manual
Action Press Details
14.Setforceddoor
output time
45#ttt#0#**
ttt=forced d oor time, to
nearest 10’s seconds,
entered a s 00-990 (00
latches it); default=10
secs
15. Clear eeprom
memory and restore
default settings
46 # 00000 # 00000 # **
(See page 2)
User Types
0-toggle code
1-standard access
2-Log Dump
3-lockout
4-extended lockout
5-single use
6-relock code
7-emergency
16a. “Code only” user
50#type#location#keypin*keypin*
16b. “Card only” user
by presentation
50#type#location#**<presentcard>
16c. “Card AND code”
user
50#type#location#keypin*keypin*
<present card>
16d. Delete user
50#0#location#**
17. Program 26-bit
“card only” user without
presenting card
51#type#location#cardpin*cardpin*
Location must be
greater than 2;
master/supervisor
cannot be set as “card
only”
18. Program “card OR
code” user
52#type#location#keypin*keypin*
<present card>
19. Program
consecutive “card only”
users by presentation
53 # type # start user # ** <present card>
<present card> ...
Startusermustbe
greater than 2;
master/supervisor
cannot be set as “card
only”
20. Enable/disable users
56 # enable/disable # user # **
0=Enablesthatuser
1=Disablesthatuser;
master user cannot be
disabled; an
unprogrammed user
cannot be enabled or
disabled (generates a
program error)
21. Program block of
26-bit “card only” users
without presenting cards
57#numberofusers#startuser#cardpin*
card pin *
Startusermustbe
greater than 2;
master/supervisor
cannot be set as “card
only”; uses site ID set
in command 32,
parameter 4
Program Commands (cont inu ed)
Prox.pad plus Access System Installer Guide
20 Part No. 6045679, Rev. 1.0, D5