User's Manual
Program Commands
In addition to personal computer (PC) programming, the prox.pad plus unit can be
programmed manually using the keypad on each unit and without the use of a personal
computer and software. Keypad programming can be helpful to get a door or doors up and
running prior to having the availability of the host computer. In all cases, the personal com-
puter programming options supersede the keypad programming options.
Defaults are in bold. See the prox.pad plus Installation/Programming Manual located on the
supplied CD-ROM for further details.
Action Desired Press Details
To enter program
mode
99 # (Master Code) *
Default Master code =
1234.
Yellow LED blinks slowly
1. Change master code
Code-only operation
(example, 4321 master
code)
1 # (new code) * (repeat code) *
1 # 4321 * 4321 *
2. Assign outputs
10 # v irtual output # physical output # **
Virtual Output Physical Output
1-Lock 1-Relay1(Main)
2 - Alarm Shunt 2 - Relay 2 (Aux)
3-ProppedDoor 5-AudioAlert#1
4-ForcedDoor 6-AudioAlert#2
Entering a zero (0) for a
virtual output disables
the physical output
3. Set lock output
duration
11 # tt # 0 # * *
tt = number of seconds
to operate lock on
access (1 through 255)
defaults to 5 seconds
4. Delete users
user-location # **
5. Set/clear keypad
options
30 # option # set/clear # **
See options below
Option Set/Clear
0-audio keypress feedback 0=off, 1=ON
1-visual keypress feedback 0=off, 1=ON
2-auto entry enable 0=OFF, 1=on
3-Card and PIN required for 0=OFF,1=on
Program mode
5-user lockout enable 0=off, 1=ON
7-internal REX select 0=OFF,1=on
8-user lockout select 0=BY LOCATION,
1=by group
9-timezones select 0=OFF,1=on
10-holiday timezone midnight 0=off, 1=ON
crossing
11-auto-unlock select 0=OFF,1=on
12-first-in auto-unlock 0=OFF,1=on
13-daylight savings time select 0=off, 1=ON
15-daylight savings time format 0=USA,
1=European
16-anti-passback 0=off,1=ON
17-user dump select 0=all users
1=programmed
users only
Prox.pad plus Access System Installer Guide
18 Part No. 6045679, Rev. 1.0, D5