User Manual

15
Programming Instructions for Keypad Operations
Only
8
Soflink Plus must be used with (PA) controller for programming
The Master Code is always User 01. The Master Code assigns the Emergency and
Supervisory Codes. It is also used for programming. Users are deleted through the Master
Programming Code only
The Emergency Code is always User 02. The Emergency Code will override the deadbolt
in the mortise lock and has an unlock time of 10 seconds
The Supervisory Code is always User 03. The Supervisory Code allows temporary lockout
of selected users, changes duration of unlock time, requests infrared interrogation output,
may add additional User Codes and entry when low battery has expired
The first User Code will be User 04 or higher. User numbers do not have to be used or
entered sequentially
To Begin Programming:
The Keypad Mortise Lock is preset at the factory with Master Code 1234. Entering 1234
*
will unlock the lock allowing the lever handle to retract the latchbolt.
Initial Set-Up Procedures:
The following are typical procedures to follow when setting up your 8200 Series Keypad
If a mistake is made during any of procedures, depress the * several times until
the yellow LED goes out
If no keystroke is made in a 30sec time frame the programming up to that point
will default and you will have to start over
LK Programming
To determine which programming steps to use for your lock see the example
below:
If your label has an LK, then use the programming below.
If your label has an LU or PK, turn to the next set of programming.
Change Master Code (This Example uses the Factory Default Master)
99# 1234* Yellow LED Blinks
50# 1# 01# New Master Code* Yellow LED Blinks Quickly
New Master Code* Yellow LED Blinks Slowly (If Solid, see Note)
* Yellow LED Goes Out
-
+
-
+
-
+
-
+
+
-
+
-
LK