User's Manual
A7817A
8
Section 3: System Configuration
This section explains how to configure your Profile Series vN.1 Access Control Lock
system. Each sub-section describes the various configuration options. At the end
section 3 there is a chart that shows all the dip-switch settings for quick reference.
3.1 Selecting the Reader Address
One Interface Module can support from one to four Readers. You must assign each
Reader an address before you connect it to the Interface Module. Each Reader must
have a different address assigned to it. This enables the Interface Module to distinguish
each Reader from one another. The Reader address is selected by configuring dip-
switches 1 and 2 on switch SW2 on the rear of the Reader board. The chart below
shows these switch settings.
Reader Address Switch 1 Switch 2
Reader #1 Open Open
Reader #2 Closed Open
Reader #3 Open Closed
Reader #4 Closed Closed
Once you’ve assigned the Reader addresses you now must configure the Interface
Module to communicate with them. This is done by selecting which Readers are
connected using dip-switches 1 through 4 on switch S2 on the Interface Module. To
select a Reader close the corresponding switch and if a Reader is not connected leave
the switch open. The chart below shows these switch settings.
Switch Function Open Closed
1 Reader 1 Select Reader 1 Not Connected Reader 1 Connected
2 Reader 2 Select Reader 2 Not Connected Reader 2 Connected
3 Reader 3 Select Reader 3 Not Connected Reader 3 Connected
4 Reader 4 Select Reader 4 Not Connected Reader 4 Connected