User's Manual
A7817A
10
3.5 Dip-Switch Setting Chart
The charts below show all the dip-switch settings on the Interface Module and the
Reader. If a switch is not used, leave it open.
Reader Switch S1
Dip-Switch Function Open Closed
1 Not Used N/A N/A
2 Not Used N/A N/A
3 Not Used N/A N/A
4 Solenoid Select N/A Solenoid
5 Fail Safe/Fail Secure
Select
Fail Safe Fail Secure
6 Red LED Select Red LED Off Red LED On
7 Tamper Input Select Tamper Disabled Tamper Enabled
8 Not Used N/A N/A
Reader Switch SW2
Dip-Switch Function Open Closed
1 Reader Address
Select
See section 3.1
2 Reader Address
Select
See section 3.1
3 Not Used N/A N/A
4 Not Used N/A N/A
Interface Module Switch S1
Dip-Switch Function Open Closed
1 Not Used N/A N/A
2 Not Used N/A N/A
3 Green LED
Operation
Pull Led control terminal
low to operate
Pull Led control
terminal high to
operate
4 Tamper Operation Tamper only activates
when magnet removed
Tamper activates if
any door goes offline
Interface Module Switch S2
Dip-Switch Function Open Closed
1 Reader 1 Select Reader 1 Not Connected Reader 1 Connected
2 Reader 2 Select Reader 2 Not Connected Reader 2 Connected
3 Reader 3 Select Reader 3 Not Connected Reader 3 Connected
4 Reader 4 Select Reader 4 Not Connected Reader 4 Connected
5 Not Used N/A N/A
6 Not Used N/A N/A
7 Not Used N/A N/A
8 Not Used N/A N/A