User Manual
Action Press Details
21. Set/clear event
log mask
73#event#set/clear#**
All events are
logged by default
Event
0=unknown event
1=access denied, invalid PIN
2=program denied
4=REX
5=Propped Door
6=Dood Closed
7=Forced Door
17=access granted to user #N
18=access denied to user #N, user
group lockout
19=access denied to user #N, bad time
zone
20=passage mode activated by user #N
(latch set)
21=passage mode deactivated by user
#N (latch clear)
22=1st in auto-unlock triggered by user
#N
23=door relocked by user #N
24=user lockout enabled by user #N
25=userlockoutdisabledbyuser#N
26=access denied to user #N, user is
disabled
27=card/code mismatch
29=program mode started by user #N
30=log erased by user #N
31=comm enabled by user #N
22. Reset (erase)
transaction log
76 # 00000 # 00000 # **
1.5 Programming Commands
1-32 DoorGard LS2/LS2P System Programming Manual, D3