Action Desired Press Details
3. Change keypad
parameters
32#parameter#value#**
See parameters
0-7 below
Parameter Value
0, error lockout 1-50 (def=3)
threshold
1, error lockout duration 1-255 (def=10)
2, door loop audio 0-3 (def=0)
output select 0=no door loop
audio outputs
1=forced door
audio output on
2=propped door
audio output on
3=both forced &
propped door
audio outputs on
3, extended unlock 1-255 (def=10)
4, site ID (for cmds 51 0-255 (def=11)
and 57)
5, user timezone mask 0-255 (def=255)
(for programming
users through faceplate)
6, user lockout group 0-15 (def=4)
(for programming
users through faceplate)
7, lockout by group 0-3 (def=0)
operand 0=lockout users
in all other
groups
1=lockout users
in this group
(except lockout
users)
2=lockout users
in higher num-
bered groups
3=lockout users
in lower num-
bered groups
1.5 Programming Commands
1-28 DoorGard LS2/LS2P System Programming Manual, D3