User Manual

1.4.3
Enabling/Disabling
Users Command
The 56#set/clear#userLocation#command allows
themastercodeorsupervisorcodetodisableacertain
user location without deleting that user.
To disable a user, enter:
56#1#userlocation#**
To enable a user, enter:
56#0#userlocation#**
The master code can NEVER be disabled.
ThemastercodecandisabletheSupervisoruser
(user # 2).
The Supervisor can disable users 3-2000.
The Master Code user cannot be disabled, and the
supervisor user cannot disable his/her self. A disabled
supervisor cannot access program mode; a non-pro-
grammed user cannot be enabled or disabled (gener-
ates a program error).
1.4.4 Adding New or
Changing Existing
Codes
The most basic DoorGard LS2/LS2P programming is
adding new codes (users), or modifying existing codes
(users). Each user entry consists of three parameters:
ausertype,alocationandakeypad-PINand/orCard.
These eight specific types of users can be programmed
with the DoorGard LS2/LS2P system:
0= toggle
1= standard access
3=lockout
4=extended unlock
5= single use
6=relock code
7= emergency
8=communications enable
The following procedure adds a new code, or lets you
change an existing code.
1. Place the DoorGard LS2/LS2P system in program
mode. Press:
99 # Master Code * (default is 1234 or 99#
Supervisor code)
1.4 Programming Users
DoorGard LS2/LS2P System Programming Manual, D3 1-23