User Manual

1.4 Programming
Users
1.4.1 User Features
The LS2/LS2P system can store up to 2000 users with
codes being from one to six digits in length. The first
user (user location 1) is designated as the “master code”
and the second user (user location 2), when added, is
designated as the “supervisor.” The master code has
access to all the programming commands. The super-
visor only has access to adding/deleting users with the
various commands (50, 51, 52, 53, 56, 57, and 58) and
the lock duration command (11).
This also means the supervisor has access to command
32 options 5 and 6. Please note that the Master Code
(user #1) and Supervisor Code (user #2) can only be
programmed as standard users.
Both the Master and Supervisor users can be pro-
grammed as “card AND code” or “card OR code.”
When either are programmed as “card AND
code,” both are also required to enter program
mode.
Whentheyare“cardORcode”only,thecodeis
required to enter program mode.
There is a feature to allow “card OR code” master
and supervisor to require both to enter program
mode. (This feature is enabled/disabled in com-
mand 30 option 3 and is disabled by default.
Themasterorsupervisorcannotbesetto“card
only.”
The LS2/LS2P supports eight different user types,
which are identified and described in Table 1-4.
1.4 Programming Users
1-20 DoorGard LS2/LS2P System Programming Manual, D3