User Manual
2. To enable this feature, press:
30#1#1#**
The yellow LED continues to blink slowly. (A
steady yellow LED, in contrast, means that errors
were detected during programming. Error states
can be cleared by pressing the asterisk * key.)
3. To disable this feature, press:
30#1#0#**
The yellow LED continues to blink slowly.
4. Press * to exit program mode.
1.3.9 Auto Entry
Auto Entry, which is disabled by default, can be en-
abled by entering the following Set/Clear Platform
command (see Table 1-5 for details). To disable, enter:
30#2#0#**
When Auto Entry is enabled, you are not required to
enter the asterisk (*) after your code. To enable, enter:
30#2#1#*
This only applies to codes the same length as the
master.
If, for some reason, you need a code longer than the
master code, press # before the desired code followed
by * (asterisk). This is called “auto-entry suspend.”
Example: if the master code is 4 digits and your code
is 23456, press #23456*
1.3.10
TimeZone/Holiday
Features
The LS2/LS2P system currently supports up to eight
(8) timezones. Timezones are disabled by default and
can be enabled with Command 30 option 9. To disable,
enter:
30#9#0#**
Auto-Unlock is also disabled by default and can be
enabled with Command 30 option 11. The default
auto-unlock timezone is in location 8 and is 9:00 A.M.
to 5:00 P.M. Monday through Friday. To make this
1.3 Programming Keypad Options and Parameters
1-12 DoorGard LS2/LS2P System Programming Manual, D3