User Manual
the Lockout By Group “operand” in Command 32
parameter 7 to one of the following values:
• 0 = lockout all other groups
• 1=lockoutjustthisgroup
• 2 = lockout higher numbered groups
• 3 = lockout lower numbered groups
When a “lockout just this group” is activated, all users
in that group are locked out with the exceptionof those
users programmed as Lockout Codes. This allows the
user who initiated the lockout to cancel the lockout.
1.3.6 Error Lockout
Option
The LS2/LS2P system supports error lockout, which is
always enabled and cannot be disabled. When the
lockout threshold (set with command 32 parameter 0,
defaults to 3) is reached, the keypad locks up and the
yellow LED turns on (it does not process codes) until
the lockout duration expires (lockout duration is set
with command 32 parameter 1, defaults to 10 seconds).
Example:
32 # parameter # value # **
[0, error lockout threshold1-50 (default=3)
1, error lockout duration1-255 (default=10)]
When the lockout duration is activated, the yellow
LED on turns on for 5 seconds and shuts off. When
the keypad wakes up and error lockout is still active,
the LED turns back on for an additional 5 seconds.
This is to preserve battery life.
The count is cleared after a correct code is entered or
if the DoorGard LS2/LS2P system goes to sleep.
1.3.7 Turning Audio
Keypress Feedback
ON/OFF
The Audio Keypress Feedback command enables the
sounder to beep once for each key press. This feature
provides an audio acknowledgment that a particular
key was pressed hard enough for the system to un-
derstand. The factory-shipped default setting is ON,
butitcanbetoggledONandOFFasdesiredusing
1.3 Programming Keypad Options and Parameters
1-10 DoorGard LS2/LS2P System Programming Manual, D3