User Manual

1.3 Programming
Keypad Options
and Parameters
1.3.1 Set Lock Time
The Set Lock Time feature is enabled by using this
command:
11 # tt # 0 # * *
where tt = numberof seconds to operate lock on access
(1 through 99)
The default is 5 seconds.
1.3.2 Propped and
Forced Door Audio
Alerts
The LS2/LS2P system support both Propped Door and
Forced Door Audio Alerts. By default both audio alerts
are disabled, but can be activated using command 32
parameter 2. Please note this parameter only controls
the audio alerts. These features cannot be disabled by
setting the parameter to 0, meaning the door loop is
always active and continues to record these transac-
tions, when door contacts are used, even though there
is no audio alert.
The door loop is Normally Open, meaning you must
close the loop to activate either function.
Action Press Details
Change keypad
parameters
32#parameter#value#**
See below
Parameter Value
2, door loop audio 0-3 (def=0)
output select 0=no door loop
audio outputs
1=forced door
audio output on
2=propped door
audio output on
3=both forced &
propped door
audio outputs on
1.3 Programming Keypad Options and Parameters
1-6 DoorGard LS2/LS2P System Programming Manual, D3