User`s manual
Chapter 4 — Troubleshooting and Maintaining the Printer
108 PF2i and PF4i Mid-Range Printer User’s Manual
Adjusting the Label Stop Sensor
The LSS can be moved laterally between five fixed positions.
To adjust the LSS
1 Use a small screwdriver to push the sensors in as far as possible.
2 One at a time, pull the sensors out while counting the clicks.
To test the LSS
1 Make sure that your printer is properly configured for the type of
media you are using. Go to SETUP > MEDIA > MEDIA TYPE.
2 Open the media cover.
LSS Positions
Position Distance
One click out 3 mm (0.118 in)
Two clicks out 8 mm (0.315 in)
Three clicks out 12 mm (0.472 in)
Four clicks out 16 mm (0.639 in)
Five clicks out 20 mm (0.787 in)
Upper part of LSS
Print mechanism
One diode +
One sensor
One diode +
One sensor
Lower part of LSS