User`s manual
Chapter 5 — Using the IF30 GPIO Interfaces
76 IF30 Fixed Reader User’s Manual
• Switching the high side, with the load powered externally.
• Driving a DC relay that controls an AC load.
Switching the High Side Using IF30 Power
In this example, an external indicator lamp with a 0.25A maximum
current is connected to the -Output and Ground pins, and the
corresponding +Output pin is connected to the +12 VDC source.
Switching the High Side
Switching the Low Side Using IF30 Power
For low side switching applications, the lamp is routed to all the
lamps in common and the low side of the load is routed to the switch.
In this method, connect the external indicator lamp to the +Output
and +12 VDC pins, and short the corresponding
-Output pin to ground as shown.
Switching the Low Side
External
indicator lamp
0.25A maximum
+Output
+12 V
Ground
-Output
External
indicator lamp
0.25 A maximum
Ground
-Output
+Output
+12 V