User`s manual
Chapter 3 — Creating and Using RFID Applications
50 IF30 Fixed Reader User’s Manual
then click Save Changes and Reboot. For help, see “Saving
Configuration Changes” on page 16.
Viewing the DCE Events Log
If you enable DCE logging, you can see a list of commands sent and
received through the DCE. You can save the logfile as a .txt file.
To enable DCE logging and view the logfile
1 From the menu, click RFID Module > DCE Configuration. the
DCE Configuration screen appears.
DCE Configuration Parameter Descriptions
Parameter Description
Allows External
BRI
Connections
Enables/disables external TCP connections to the DCE BRI
server.
BRI TCP Port Specifies the TCP port used for incoming BRI connections
to the DCE. This port must be unique for all TCP services
running on the IF30. Valid range is 0 to 65535. Default is
2189.
BRI Heartbeat Enables/disables asynchronous heartbeat event (EVT:
HEARTBEAT BRI STRING). When enabled, the IF30 sends
the heartbeat event every 30 seconds, enhancing the IF30’s
ability to detect TCP sessions that were not closed cleanly.
Trigger
Management
Enables DCE control of trigger states.
When Trigger Management is enabled, the DCE manages
the triggers so your application never needs to issue a
TRIGGERREADY command.
When Trigger Management is disabled, your application
must manage issuance of the TRIGGERREADY command.
Allow External
EPC
Connections
Enables/disables external TCP connections to the DCE
EPC server. When this box is not checked, the DCE accepts
EPC connections only from applications residing on the
IF30.
EPC TCP Port Specifies the TCP port used for incoming EPC Reader
Protocol connections to the DCE. This port number must
be unique for all TCP services running on the IF30. Valid
ranges is 0 to 65535. Default is 4684.
Enable Logging Enables/disables logging of commands sent and received
through the DCE.