User`s manual
Chapter 3 — Creating and Using RFID Applications
IF30 Fixed Reader User’s Manual 47
Antenna Tries
Sets the maximum number of ID Tries that the reader executes per
antenna. Valid range is 1 (default) to 254.
This setting is equivalent to the ANTTRIES BRI attribute.
Read Tries
Sets the maximum number of times the read algorithm is executed
before a response is returned to a Read command.
In practice, this is the number of times an identified tag will be read
until the read is successful. Valid range is 1 (default) to 254.
This setting is equivalent to the RDTRIES BRI attribute.
Write Tries
Sets the maximum number of times the write algorithm is executed
before a response is returned to a Write command.
In practice, this is the number of times an identified tag will be
written until the write is successful. Valid range is 1 to 254. The
default is 3.
This setting is equivalent to the WRTRIES BRI attribute.
Initialization Tries
Sets the maximum number of times the reader attempts to initialize a
tag. Valid range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.
Lock Tries
Sets the maximum number of times the lock algorithm is executed
before a response is returned to a Lock command. Valid range is 1 to
254. The default is 3.
This setting is equivalent to the LOCKTRIES BRI attribute.
Select Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of
times a group select is attempted. A group select is the command that
starts the identity process. Valid range is 1 (default) to 254.
This setting is equivalent to the SELTRIES BRI attribute.