Chapter 3 — Creating and Using RFID Applications
46 IF30 Fixed Reader User’s Manual
ID Report
Enables or disables tag ID reporting after a Read, Write, or Lock
command is executed:
For ISO tags, the tag identifier corresponds to TAGID.
For EPC tags, the tag identifier corresponds to EPCID.
Check the check box to enable tag ID reporting.
This setting is equivalent to the IDREPORT BRI attribute.
No Tag Report
Enables or disables a NOTAG message, which is sent when no tags are
found during execution of a Read, Write, or Lock command. Check
the check box to enable the message.
This setting is equivalent to the NOTAGRPT BRI attribute, and is
enabled by default.
Timeout Configuration Mode
Enables a timeout mode. Instead of specifying the number of antenna
or ID tries, you specify a timeout value. If the IF30 does not find any
tags after an antenna or ID try, the reader waits for the specified time
before starting the next antenna or ID try.
This setting is equivalent to the TIMEOUTMODE BRI attribute, and
is disabled by default.
To enable Timeout Configuration Mode
1 Check the check box and then click Save Changes. The screen
refreshes. The Antenna Tries setting is replaced by Antenna
Timeout, and the ID Tries setting is replaced by the ID Timeout.
2 Specify the value (in ms) for the timeout in the entry fields and
then click Save Changes.
ID Tries
Sets the maximum number of times the reader executes the identify
algorithm before a response is returned to a Read or Write command.
In practice, this is the number of times a tag ID attempt is made for
each antenna being used. Valid range is 1 to 254. Default is 3.
This setting is equivalent to the IDTRIES BRI attribute.