User`s manual

Chapter 2 — Configuring Network Settings
36 IF30 Fixed Reader User’s Manual
Password Parameter Descriptions
Parameter Descriptions
Use RADIUS for
Login Authorization
Determines if you are using a password server to
authenticate logins to this IF30. Uncheck this check
box if you are not using a password server.
User Name Enter the user name you need to use to log in to this
IF30. The user name can be from 0 to 32 characters
long.
If you leave the user name and password fields blank,
a user will not need to log in to the IF30.
Password Enter the password you use to log in to this IF30. This
password gives you read and write access to the IF30
configuration. The password can be from 0 to 32
characters long.
If you leave the user name and password fields blank,
a user will not need to log in to the IF30.
Read Only Password Enter the password you need to use to log in to this
IF30. This password gives the user read-only access to
the IF30. This user can view the configuration and
execute diagnostics but cannot perform any tasks
that affect IF30 operation, such as changing
configuration options or downloading software.
To disable this password, delete it.
Allow Service
Password
If the user enters a login that does not match either
the user name and password or the read only
password, this setting (enabled by default) allows the
login to be checked against the service password.
Intermec Product Support may use this service
password if they need to troubleshoot this IF30.
If this feature violates your security guidelines, you
may disable the service password by unchecking the
check box. If you disable the service password and
forget your normal password, you will need to contact
Product Support for instructions on resetting all
passwords to default values.