Technologies Network Router User Manual

SECTION 6 " Indicator Lights
6710 Access Point Users Guide 6-3
STATUS
The STATUS (left) light indicates the access points
operating status. When the light is OFF, the access point is
operating normally. When the light is ON, it is in error
mode.
"
NOTE: In certain cases the following text refers to the indicator lights by
number. Lights are numbered from left to right. Light 1 is labeled
LINK and Light 8 is labeled NIC2.
The access point enters error mode when it detects a
malfunction during the power-on self tests or when certain
hardware malfunctions occur during normal operation.
When the STATUS light is ON to indicate the error mode,
indicator lights 4 through 8 (the STATUS MODE light and
the NETWORK and PCMCIA light pairs) display a binary
error status code between 1 and 31. This code indicates the
specific condition causing the error status as shown in
Table 6-2. Descriptions of errors are on page 6-4.
Table 6-2
Error Mode Status Codes
Status Mode R-LINK W-LINK NIC1 NIC2 Error Status
ON OFF OFF OFF OFF ON Hardware error 1.
ON OFF OFF OFF ON OFF Hardware error 2.
ON OFF OFF OFF ON ON Hardware error 3.
ON OFF OFF ON OFF OFF Internal serial loop-
back test failed.
ON OFF OFF ON OFF ON Internal MACE AUI
loopback test failed.
ON OFF OFF ON ON OFF Internal 10BASE-T
loopback test failed.
ON OFF OFF ON ON ON Timer test failed.