User's Manual
8 MobileLAN WA21 Radio Replacement Instructions
Closing the Access Point
1 Install a new gasket along the inside edge of the top cover. To
maintain IP 54 rating, do not reuse the original gasket.
2 Insert the tab on the LED flex assembly into the connector on
the main PCB.
3 Place the bottom cover on the top cover. Verify that the
gasket is in place.
4 By hand, begin screwing in the seven screws you removed
when you opened the access point.
5 Use 18 in-lb of torque to tighten the screws, following the
torque sequence shown in the next illustration. You may need
to retighten screws one through three after you complete the
initial sequence.
Gasket
Alignment
2100I.003