Fixed Offered for engineers and larger companies interested in more
comprehensive testing.
CW/Modulation/Pluse as shown in Figure 14.
CWTo test Output Power Linearity for the desired frequency.
ModulationTo test the Mask for the desired frequency.
PluseTo test ETSI 302 208 v1.3.1
Time- only used for modulation setting.
Figure 14
3.2.5. Gen2 Setting
This could let you modify the Gen2 profile between the RFID ME
TM
HW and the EPC tag as
shown in Figure 15. For more details regarding these settings please reference the Class 1
Generation 2 UHF Air Interface Protocol Standard “Gen 2” at
http://www.epcglobalinc.org/standards/uhfc1g2
Default Setting
Link Frequency160KHz
SessionS0