User's Manual
RFID HW GUI User Manual
- 12 - Apr 26, 2011
Fixed : Offered for engineers and larger companies interested in more
comprehensive testing.
CW/Modulation/Pluse as shown in Figure 14.
CW:To test Output Power Linearity for the desired frequency.
Modulation:To test the Mask for the desired frequency.
Pluse:To test ETSI 302 208 v1.3.1
Time- only used for modulation setting.
Figure 14
3.2.5. Gen2 Setting
This could let you modify the Gen2 profile between the RFID ME
TM
HW and the EPC tag as
shown in Figure 15. For more details regarding these settings please reference the Class 1
Generation 2 UHF Air Interface Protocol Standard “Gen 2” at
http://www.epcglobalinc.org/standards/uhfc1g2
Default Setting:
Link Frequency:160KHz
Session:S0