UPC/EAN
UPC/EAN are fixed-length, numeric, continuous symbologies that use
four element widths.
Action
Tap (+) to expand the UPC/EAN parameter, select the setting to be
changed, then select an option to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.6.1
Options
UPC A 0 Not active
1 Active (default)
UPC E 0 Not active
1 Active (default)
EAN 8 0 Not active
1 Active (default)
EAN 13 0 Not active
1 Active (default)
Add-on digits 0 Not required (default)
1 Required
Add-on 2 digits 0 Not active (default)
1 Active
A dd-on 5 digits (Not supported when using an imager):
0 Not active (default)
1 Active
UPC A check digit 0 Not transmitted
1 Transmitted (default)
UPC E check digit 0 Not transmitted
1 Transmitted (default)
EAN 8 check digit 0 Not transmitted
1 Transmitted (default)
EAN 13 check digit 0 Not transmitted
1 Transmitted (default)
UPC A number system 0 Not transmitted
1 Transmitted (default)
UPC E number system 0 Not transmitted
1 Transmitted (default)
UPC A re-encoding 0 UPC A transmitted as EAN 13 (default)
1 UPC A transmitted as UPC A
UPC E re-encoding 0 UPC E transmitted as UPC E (default)
1 UPC E transmitted as UPC A
EAN 8 re-encoding 0 EAN 8 transmitted as EAN 8 (default)
1 EAN 8 transmitted as EAN 13