User's Manual

Table Of Contents
Control Panel AppletsAppendix A
292 700 Series Color Mobile Computer User’s Manual
Codabar
Codabar is a self-checking, discrete symbology.
Action
Tap (+) to expand the Codabar parameter, select a setting to be changed,
then select an option from the drop-down list to change this setting.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.5.1
Options
Decoding 0 Not active (default)
1 A ctive
Start/Stop 0 Not transmitted (default)
1 abcd transmitted
2 ABCD transmitted
3 abcd/tn*e transmitted
4 DC1`DC4 transmitted
CLSI library system (Not supported when using an imager):
0 Not active (default)
1 A ctive
Check digit 0 Not used (default)
1 Transmitted
2 Not transmitted
Bar code length 0 Any length
1 Minimum length (default)
2 Fixed lengths
Minimum length 003-254 Minimum length 3-254 (6)
Fixed length 1 000-254 Fixed length 0-254 (0)
Fixed length 2 000-254 Fixed length 0-254 (0)
Fixed length 3 000-254 Fixed length 0-254 (0)
Note:IfBar code length =“1”thenMinimum length is entered. If Bar
code length =“2”thenFixed length 1, Fixed length 2,orFixed length 3
is entered.