User's Manual

Table Of Contents
Control Panel AppletsAppendix A
290 700 Series Color Mobile Computer User’s Manual
Code 39
Code 39 is a discrete, self-checking, variable length symbology. The char-
acter set is uppercase A-Z, 0-9, dollar sign ($), period (.), slash (/), percent
(%), space ( ), plus (+), and minus (-).
Action
Tap (+) to expand the Code 39 parameter, select the setting to be changed,
then tap an option to change this setting or select an option from the
drop-down list.
SNMP OID
1.3.6.1.4.1.1963.15.3.3.1.1.3.1
Options
Decoding 0 Not active
1 Active (default)
Format 0 Standard 43 characters (default)
1 Full ASCII
Start/Stop 0 Not transmitted (default)
1 Transmitted
Start/Stop characters (Not supported when using an i mager):
0 $ (dollar sign) only
1 * (asterisk) only (default)
2 & and * (dollar sign and asterisk)
Check digit 0 Not used (default)
1 Mod 43 transmitted
2 Mod 43 not transmitted
3 French CIP transmitted
4 French CIP not transmitted
5 Italian CPI transmitted
6 Italian CPI not transmitted
Bar code length 0 Any length (default)
1 Minimum length
Minimum length 000-254 Minimum length 1-254 (6)
Note:IfBar code length =“1”thenMinimum length is entered.