Cut Sheet
Nonmetallic Hub Kit
for Direct Connection to
12 Volt and 120 Volt
Underwater Luminaries
1. Install the Nonmetallic Hub to enclosure using
Cable Clamp supplied.
2. Install rigid nonmetallic conduit between
luminaire and Hub.
3. Pull conductors from luminaire to enclosure.
4. Connect supply conductors to conductors from
luminaire.
5. Ground and bond installation as required by
Code.
6. Tighten Cable Clamp screws to secure cord and
provide strain relief.
7. Apply Duct Seal as required by Code.
Order Hub Kits through
your Intermatic Distributor.
Kit Numbers 156PA13713A (1/2”),
156PA13714A (3/4”), & 156PA13715A (1”)
1. Install the Nonmetallic Hub to enclosure using
Cable Clamp supplied.
NOTE: The Low Voltage Compartment Divider
Plate may be removed for ease of installation.
2. Install rigid nonmetallic conduit between
luminaire and Hub.
3. Pull conductors from luminaire to enclosure.
4. Connect secondary conductors from transformer
to conductors from luminaire.
5. Ground and bond installation as required by
Code using pressure terminal provided in low
voltage compartment of enclosure.
NOTE: If your control panel has a pressure
terminal that is separate from the ground bar,
bonding the two bars together is not necessary.
6. Tighten Cable Clamp screws to secure cord and
provide strain relief.
7. Apply Duct Seal as required by Code.
8. Replace Low Voltage Compartment Divider Plate
if removed. Tighten screw securely.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158PA11511
High Voltage
Lighting Systems
Low Voltage
Lighting Systems
INSTALLATION INSTRUCTIONS