User Guide
SKIP STEPS 5 AND 6 If LOW VOLTAGE RACEWAY
IS PRESENT IN ENCLOSURE AS THIS PROVIDES
THE REQUIRED SEPARATION OF CIRCUITS
Step #5
If there is not enough corrugated tubing
available in the kit to install two separate tubes,
a splice connecting one tube to the adjacent
tube is acceptable.
Step #5
Cut the corrugated tubing so there is enough
length to reach from the bottom of the control
down to the shutter bushing. Slip the tubing
over the freeze probe cord.
Step #6
Included in the Class 2 Wiring Isolation Kit is a
Cable Tie Retainer. Use this retainer to secure
the top of the corrugated tubing to the back of the
Intermatic enclosure, as close to the bottom of the
mechanism as possible.
INTERMATIC INCORPORATED
http://www.intermatic.com
Intermatic Plaza, Spring Grove, Illinois 60081-9698
158PA11041
Step #7
1. Use the program key to save and advance
to the Freeze Temperature setting.
The 1st circuit is the factory selected default, and
32°F is the default temperature setting.
2. Use the Up and Down arrow keys to increase
or decrease the desired freeze temperature trip
point. The range available is 32°F thru 44°F.
3. After you have selected the proper temperature,
push and release the desired ON/OFF keys to indi-
cate which circuits should come ON when freeze
condition exists.
4. When programming is complete, push and
release the Enter key or Program key to end your
programming session.
FOR FREEZE PROGRAMMING INSTRUCTIONS
REFER TO YOUR MULTIPURPOSE CONTROL
MANUAL FOR COMPLETE INSTRUCTIONS,
OR STEP #7 FOR A QUICK REVIEW
Intermatic Mechanism
Corrugated Tubing
Shutter Bushing
Freeze Probe Cord
Intermatic Mechanism
Enclosure
Cable Tie Retainer
Corrugated Tubing
Connect to
Mechanism
Adjacent Tube
Splice
Example #2
Example #1
Cable Tie Retainer
Conduit attached
To enclosure
158PA11041.indd 2 2/5/09 2:37:41 PM