Specification

www.intermatic.com
Energy Controls
IOS-DSR Series
Specification
The sensor shall be capable of detecting presence in the control area by detecting changes in infrared energy. The
sensor shall utilize zero crossing circuitry on relay to reduce stress on relay and increase sensor life. The sensor shall
have no minimum load requirement and shall be capable of switching from 0 to 800 Watt incandescent; 0 to 800 Watt
uorescent or
1
4 HP @120 VAC, 60 Hz; and 0 to 1600 Watt uorescent @ 277 VAC 50/60 Hz. The sensor shall cover up
to 1,200 sq. ft. for walking motion, with a eld view of 180 degrees. The sensor shall have a time delay ranging from 15
seconds to 30 minutes. In automatic mode, the sensor shall be capable of automatically returning to Automatic-ON after
lights are turned off manually. The sensor shall have an LED indicator that remains active at all times to verify detection in
the controlled area. The sensor shall have a limited 5-year warranty and shall be UL and CUL listed. The sensor shall be
Intermatic model_______________(White-IOS-DSR-WH)(Ivory-IOS-DSR-IV).