Owner's Manual

Typical Wiring Diagrams
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer and Load
H
N
TO LOAD
T
TO 208/240V LINE
TIMER NCNOCOM
1
2
3
4
5
208/240V Timer and Load
L1
L2
TO LOAD
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer 24-240V LOAD
H
N
LOAD
TO 24-240V LINE
LOW
HIGH
COM
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V TWO SPEED FAN
H
N
120V Timer, 120V Load
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer and Load
H
N
TO LOAD
T
TO 208/240V LINE
TIMER NCNOCOM
1
2
3
4
5
208/240V Timer and Load
L1
L2
TO LOAD
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer 24-240V LOAD
H
N
LOAD
TO 24-240V LINE
LOW
HIGH
COM
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V TWO SPEED FAN
H
N
208/240V Timer, 208/240V Load
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer and Load
H
N
TO LOAD
T
TO 208/240V LINE
TIMER NCNOCOM
1
2
3
4
5
208/240V Timer and Load
L1
L2
TO LOAD
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer 24-240V LOAD
H
N
LOAD
TO 24-240V LINE
LOW
HIGH
COM
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V TWO SPEED FAN
H
N
120V Timer, 24V, 120V, or 240V Load
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer and Load
H
N
TO LOAD
T
TO 208/240V LINE
TIMER NCNOCOM
1
2
3
4
5
208/240V Timer and Load
L1
L2
TO LOAD
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V Timer 24-240V LOAD
H
N
LOAD
TO 24-240V LINE
LOW
HIGH
COM
T
TO 120V LINE
TIMER NCNOCOM
1
2
3
4
5
120V TWO SPEED FAN
H
N
120V Two Speed Fan
GMXFM1D & GMX2FM2D Series
Electronic Time Controls
GMXFM1D20
1. Remove 2 screws retaining the interior cover panel and remove panel by
prying out with a thin blade at the top.
2. Select knockouts to be used. Remove the inner (1/2”) knockout by
inserting a screwdriver in the slot and carefully punch knockout loose.
Remove slug. If the 3/4” knockout is required, remove the outer ring with
pliers after removing the 1/2” knockout. Smooth edges with knife if
necessary.
3. Place enclosure in desired mounting location and mark the three mounting
holes.
4. Drill holes for #10 screws, start screws in holes.
5. Place enclosure over screws and tighten screws.
6. Connect conduit hubs to conduit before connecting the hubs to the enclo
sure. After inserting hubs into enclosure, carefully tighten hub lock nut.
Do not over-torque.
7. Wire in accordance with National and Local Codes.
8. Replace interior cover panel and 2 screws.
Grounding: This enclosure is of plastic construction and does not require a
ground connection and does not require bonding in pool applications.
This enclosure does not provide grounding between conduits. When using
non-metallic conduit or cable, connect the ground wires of all cables together
with a wire nut. When metallic conduit is used, use grounding type bushings
and a jumper wire between each conduit.
APPLICATION
The GMXFM1D and GMX2FM2D Series are universal electronic time switches
within UL TYPE 1 indoor or UL TYPE 3R outdoor enclosures intended for the
control of lighting, heating, air conditioning, pumps, motors, or general
electrical circuits in residential, commercial, industrial and agricultural facilities.
Basic models are:
Series Description
GMXFM1D20 1 channel SPDT 20 program electronic
GMXFM1D50 1 channel SPDT 50 program electronic
GMX2FM2D50 2 channel 2 x SPDT 50 programs
SPECIFICATIONS
Switch Rating: SPDT Switch
GMXFM1D Series Switch Ratings: GMX2FM2D Series Switch Ratings:
N.O. Contact: N.O./N.C. Contact:
-1/2hp, 120 V ac -1/2 hp, 120V ac
-1hp, 240 V ac -1hp, 240V ac
-8 A, 24 V dc resistive -16A, 277V ac resistive
-16 A, 277 V ac resistive -12A Ballast, 120V ac
-12 A Ballast, 120 V ac -8A Ballast, 240V ac
-8 A Ballast, 240 V ac -720 VA 240V ac Pilot Duty
-720 VA 240 V ac Pilot Duty -360 VA 120V ac Pilot duty
-360 VA 120 V ac Pilot Duty -1000W Tungsten, 240V ac
-1000W Tungsten, 240 V ac -600W Tungsten, 120V ac
-600W Tungsten, 120 V ac
N.C. Contact:
-16 A, 277 V ac resistive
-8 A, 24 V dc Pilot Duty
-360 VA, 120 V ac Pilot Duty
3 year Reserve (Non-Replaceable Battery)
ENVIRONMENTAL RATINGS
Ambient Temperature: –14°F to 131°F (-10˚C to 55˚C)
WIRING CONNECTIONS
Screw clamp terminals for up to AWG #10 wires
Agency Approvals: UL Listed
INSTALLATION
Note: For outdoor locations, Raintight or wet location conduit hubs that
comply with requirements of UL 514B (standard for fittings for conduit and
outlet boxes) are to be used.